Major changes are:
- Make all commands return 'ConfirmImpact.None' if `SupportsShouldProcess` is not set to `true`.
- Update some cmdlets to explicitly use `ConfirmImpact.Low`.
- Update `DefaultCommands.Tests.ps1` to test for 'ConfirmImpact' level.
Instantiating a new MediaTypeHeaderValue object fails when the -ContentType parameter includes a charset such as application/json; charset=utf-8. This makes it impossible to set the content encoding on web requests. Moving to Parse() ensures we actually get a proper MediaTypeHeaderValue when the charset is present, thus allowing users to set their request encoding via proper -ContentType values.
* Improve check for developer mode by checking minimum required build number
The test would fail if the developer mode is enabled but the machine has an older build than the minimum required build.
The change adds a check for the build version in the test.
* Update test/powershell/Modules/Microsoft.PowerShell.Management/New-Item.Tests.ps1
Web Cmdlets will no longer forcibly remove Expect: 100-continue from web requests.
This was a legacy setting that needed to be there because of platform differences that have since been resolved in CoreFX.
Fix#8028
This change adds support for specifying the underlying type for an enum:
```powershell
enum MyEnum : long
{
A = 0x0FFFFFFFFFFFFFFF
B
}
# or
enum MyByte : byte
{
A = 0x01
B = 0x02
C = 0x03
D
}
```
* support fuzzy matching with get-command and on CommandNotFound exception, show suggestion
* fix CodeFactor issues
* change algorithm to use Damerau-Levenshtein Distance which is more useful in finding close matches
Ubuntu18.04 seems to default to C.UTF-8 for LANG (representing InvariantCulture) which results in a case-sensitive hashtable since CurrentCultureIgnoreCase doesn't work for that culture. Fix is to use OrdinalIgnoreCase instead.
WriteMemberInfoCollection() calls WriteEndElement() at most once, even if WriteStartElement() has been called more than once. This commit moves the WriteEndElement() call up immediately after the elements text value has been written.
When using a screen reader or just getting the output of a table with lots of rows, the header is no longer on the screen and the columns may no longer make sense without the context. This change adds a `-RepeatHeader` switch to `Format-Table` to enable re-outputting the header after every screen full (minus 1 row). Expectation is that the user is piping the output to a pager (e.g. less) which uses the bottom row for pager information. I followed the `AutoSize` parameter as the way to get the parameter from the cmdlet into the deep formatting object where it's needed.
* Disable NewItemUnauthorizedAccessError tests.
* Added expected value for $env:HOMEPATH for user with temporary profile.
* Added a missing null check in CommandHelpProvider.cs
WebListener.exe (which was already being built) is sufficient to start web listener. Remove the dependency on `dotnet` being present to start the web listener.
Use `Start-Process` instead of `Start-Job` to launch the WebListener.
change ellipsis when truncating to single unicode character
reset console output if previous column contains ESC
update existing format-table tests
If content included a VT100 ESC sequence (like changing color), this affected all output after that cell in the table. Fix is to detect that a cell contained ESC and reset the console after it. Also, change the 3 character ellipsis `...` to use the single unicode character `…` so that more text is available.
Fix https://github.com/PowerShell/PowerShell/issues/7767